Haulin’ Water Eureka-Style!

By Mark E. Davis

On October 22-23, 2016, Chief Ira Walker Jr. and members of the Eureka Volunteer Fire Department, lin Stewartstown, Pennsylvania, had the opportunity to display their water hauling skills during a weekend rural water supply training seminar sponsored by the department. The 16-hour seminar covered all aspects of hauling water with tankers.

The weekend began with a classroom session on Saturday morning that reviewed and discussed such topics as fire flow demand, Insurance Services Office (ISO) water supply criteria, types of water hauling vehicles, modes of operation, drafting operations, dump site setup operations, and fill site operations. Saturday afternoon brought practical skill sessions on dump site and fill site operations.

1 Engine 54-4 from the Eureka Volunteer Fire Department, in Stewartstown, Pennsylvania, is a 2015 Sutphen pumper equipped with a 2,250-gpm Hale XS pump. (Photos by author.)
1 Engine 54-4 from the Eureka Volunteer Fire Department, in Stewartstown, Pennsylvania, is a 2015 Sutphen pumper equipped with a 2,250-gpm Hale XS pump. (Photos by author.)

On Sunday morning, crews conducted more practical skill sessions on dump site and fill site operations. The seminar culminated Sunday afternoon with a two-hour tanker shuttle exercise where the goal was to deliver an uninterrupted 500-gallon-per-minute (gpm) flow for two hours. The two-hour exercise is really the “old” ISO two-hour water supply drill where fire departments could demonstrate their ability to haul water in their nonhydranted areas to meet the ISO’s needed fire flows for target hazards within the community. Even though the ISO has moved to computer modeling in lieu of the two-hour drill, the drill is still a good assessment of a department’s ability to initiate and sustain a water supply operation using tankers.

Conducting the Drill

The two-hour drill comprises three time segments. The first segment lasts for five minutes and is sometimes referred to as “setup time.” Time starts on the first engine’s arrival at the designated drill site. At the five-minute mark, that engine must begin flowing water at a rate of 250 gpm-generally through some type of attack line.

The second segment of the drill lasts 10 minutes (minutes five through 15 of the drill). During this segment, water supply operations are allowed to expand using additional personnel and equipment. At the end of the 10-minute segment, the participants can increase the flow to whatever they wish. However, that flow must then be sustained for the remainder of the two-hour period.

2 Engine 54-4's pump panel is laid out for ease of operation, including the suction inlet control valves and their corresponding air primer controls.
2 Engine 54-4’s pump panel is laid out for ease of operation, including the suction inlet control valves and their corresponding air primer controls.

The third and final segment of the drill lasts 105 minutes. During this time period, the flow must not be interrupted or reduced. When the ISO used to require this drill, an interruption in flow resulted in drill failure. During training seminars, interruptions in flow and changes in flow rates are accepted as part of the learning process, and the drill continues to allow participants to overcome problems.

During the Eureka seminar, units and personnel from numerous departments surrounding the Stewartstown area participated in the two-hour tanker shuttle exercise. The results of the exercise were much better than the 500-gpm goal. At the five-minute mark, crews started with a flow of 600 gpm and then increased it to 1,100 gpm at the one-hour mark, sustaining it for the remainder of the drill.

Fire Apparatus Used

Eight tankers and five pumpers supported the two-hour exercise. At the dump site, a five-dump tank arrangement supported a supply pumper that provided water to an attack pumper via five-inch large-diameter hose (LDH). Initially, a nurse tanker operation supported the attack pumper’s flow until a dump site could be set up. Three tankers pumped off their water during the nurse tanker phase of the drill. By the time those tankers returned to the dump site from their first time being loaded at the fill site, the dump site was fully operational, and the nurse tanker operation was no longer used.

3 Engine 54-4's dual suction inlets on the officer's side.
3 Engine 54-4’s dual suction inlets on the officer’s side.

Regarding the tanker fill sites, crews used two ponds to provide three tanker-loading stations-each providing about a three-mile round trip for tankers hauling water. The first fill site had sufficient water quantity and access to support two independent loading stations. A 2,000-gpm pumper and a 1,000-gpm pumper positioned to draft from the pond and load tankers. The 2,000-gpm pumper used three suction inlets and was able to actually run two 1,000-gpm loading stations. The 1,000-gpm unit ran a third loading station. Thus that single pond could support three tankers simultaneously loading at the 1,000-gpm target loading rate.

The second fill site used a 1,500-gpm pumper to draft and support a single 1,000-gpm loading station. Access to the pond was through a cattle pasture, which limited the operation to a single pumper. The pumper loaded tankers using LDH lines.

Dump Site Pumper

The showcase of the two-hour exercise was the dump site pumper, Eureka Engine 54-4, a 2015 Sutphen pumper equipped with a Hale XS 2,250-gpm pump and four suction inlets. Engine 54-4 was designed by members from Eureka to specifically serve as a water supply unit capable of supporting all kinds of water supply operations. The pumper carries 3,200 feet of four-inch LDH in a split hosebed that is color-coded every 800 feet to indicate where to insert an inline relay valve.

The highlight of the dump site operation was Engine 54-4 drafting from four different dump tanks using all four of its suction inlets. The pumper also supplied one jet siphon transfer line from a fifth dump tank. All of this drafting was made possible-and easy-because the pumper is equipped with a Trident Auto Air Prime with multiple-location priming capability. Coupled with an inlet control valve on each suction inlet, the automatic air primer allowed Engine 54-4’s driver to easily manage drafting from four different dump tanks at the same time.

4 The final dump site arrangement comprised five dump tanks and delivered a 1,100-gpm flow.
4 The final dump site arrangement comprised five dump tanks and delivered a 1,100-gpm flow.

Once flow moved to 1,100 gpm, there were times when individual suction lines had to be shut down because of lack of water. The individual suction inlet control valves made that easy. Once water was back in a dump tank, the automatic air primer made it easy to bring that dump tank back online.

The results of the drill reinforced the importance of standardized operations and equipment-especially when it comes to loading tankers. Seeing Engine 54-4 operate as the dump site pumper reinforced the importance of carefully specifying components when designing specialty pumping apparatus.

MARK E. DAVIS is the founder and president of GBW Associates, LLC, and a fire service member for more than 30 years. He has a bachelor’s degree in education/fire science and a master’s degree in public administration. He is a certified fire protection specialist (CFPS), FADO, instructor III, and instructor trainer.

5 Engine 54-4's operator primes multiple suction inlets at the same time
5 Engine 54-4’s operator primes multiple suction inlets at the same time.